Visiting us from ?

Door Access Starter Kit

Elevator Starter Kit
$1,199.00
G2 Starter Kit
$386.00
G2 Starter Kit Pro
UA-G2-SK-Pro
$801.00
Hit the ground running with Access, featuring a professional experience for a door with two readers.

(1) Door Hub

(1) G2 Reader Pro

(1) G2 Reader for door exit, or entry for an additional door (second Hub required)

(2) Pocket Keyfobs

Installation Guide
Technical Specifications
UA-Hub-Door
Mechanical
Dimensions 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3")
Weight363 g (12.8 oz)
Enclosure material Polycarbonate
Mounting material Polycarbonate
Hardware
Networking interface (5) 10/100/1000 Base-T

Power methodPoE++
UL 294 Power-limited Class 2 PSU
UL 60950/62368 LPS/PS2 PSU
Max. power consumption Without PoE output: 30W
With PoE output: 50W
PoE input50V DC, 1A
PoE outputPoE passthrough, (4) PoE, 50V DC, total 20W
Button(1) Factory-reset
LEDsSystem: white/blue
Output relays: white
Digital inputRequest to exit/request to enter/remote release/door position sensor
Dry output relayLock: 30V DC, 1A
Aux: 30V DC, 1A
Powered output relayLock: 12V DC, 1A
Aux: 12V DC, 0.33A
12V DC, 0.33A
Operating environmentIndoor use only
Ambient operating temperature 0 to 40° C (32 to 104° F) 
Ambient operating humidity5 to 95% noncondensing
UL 294 levelDestructive attack: Level I
Line security:  Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: 1
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-Hub-Door002, V01
Wiring Information
Wiring gauge requirements (AWG)
Total length to device Output load current at 12V DC
100mA 250mA 500mA 1A       
6.1 m (20 ft) 22 22 22 18
15.2 m (50 ft) 22 22 22 18
30.5 m (100 ft) 22 22 18 18

UACC-Cable-DoorLockRelay (18 AWG) is recommended.
PoE cabling requirementsThe minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 24 AWG (0.21 mm2) for horizontal or riser cable.
LEDs
PoE inSteady blue: Adopted/device is ready
Steady white: Pending adoption
Blinking white/blue: Upgrading firmware
PoE outOff: Not connected or no data link
Steady blue: Connected and data link on
UA-G2-Pro
Mechanical
Dimensions160 x 40.4 x 40.55 mm (6.3 x 1.59 x 1.6")
Weight136 g (4.8 oz)
Enclosure materialPolycarbonate, glass
Mount materialAluminum alloy
MountingWall, gang box
WeatherproofingIP55
Hardware
Networking interface(1) GbE RJ45 port
ConnectivityBLE 4.2
NFC
Power methodPoE
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSU
Supported voltage range48V DC
Max. power consumption6W
ESD/EMP protectionAir: ±15kV, contact: ±8kV
SensorProximity sensor
Camera4000 x 3000, 12 MP, 30 FPS
MicrophoneYes
Speaker(1) 4 ohm, 1.5W
LEDsR/G/B/W
Flash
Button(1) Factory-reset
NFC frequency13.56 MHz
NFC read range< 30 mm
NFC standardsISO 14443A, 14443B, 15693
NFC technologyNFC Tag 1,2,3,4,5
MIFARE Classic
MIFAREPlus
MIFARE Ultralight
MIFARE DESFire
Operating environmentOutdoor use
Ambient operating temperatureDevice: -30 to 45° C (-22 to 113° F)
Display:* -10 to 45° C (14 to 113° F)
*The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional. (Effective after firmware v1.3.28)
Ambient operating humidity5 to 90% noncondensing
Software informationThe software version of a product can be checked at https://unifi.ui.com
UL 294 levelDestructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE cabling requirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm2) for patch cords; 24 AWG (0.21 mm2) for horizontal or riser cable.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-G2-Pro/UA-G2-Pro-Black, V02
LED
SystemSteady blue: Adopted/device is ready
Steady white: Pending adoption
Blinking white/blue: Upgrading firmware
Strobing red: Emergency lockdown
UA-G2
Mechanical
Dimensions93 x 40 x 36.5 mm (3.7 x 1.6 x 1.4")
Weight82 g (2.9 oz)
Enclosure materialPolycarbonate, glass
MountingIn wall, gang box
WeatherproofingIP55
Hardware
Networking interface(1) 10/100 MbE RJ45 port
ConnectivityBLE 4.1
Power methodPoE
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSU
Supported voltage range48V DC
Max. power consumption5W
ESD/EMP protectionAir: ±15kV, contact: ±8kV
SensorsProximity sensor
Speaker(1) 8 ohm, 0.7W
LEDsR/G/B/W
Button(1) Factory-reset
NFC frequency13.56 MHz
NFC read range< 30 mm
NFC standardsISO 14443A, 14443B, 15693
NFC technologyNFC Tag 1,2,3,4,5
MIFARE Classic
MIFAREPlus
MIFARE Ultralight
MIFARE DESFire
Operating environmentOutdoor use
Ambient operating temperature-30 to 45° C (-22 to 113° F)
Ambient operating humidity5 to 90% noncondensing
Software informationThe software version of a product can be checked at https://unifi.ui.com
UL 294 levelDestructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE cabling requirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm2) for patch cords; 24 AWG (0.21 mm2) for horizontal or riser cable.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-G2/UA-G2-Black, V02
LED
SystemSteady blue: Adopted/device is ready
Steady white: Pending adoption
Blinking white/blue: Upgrading firmware
Strobing red: Emergency lockdown
UA-Pocket
Mechanical
Dimensions84 x 39 x 7.4 mm (3.3 x 1.5 x 0.29")
Weight16 g (0.56 oz)
Enclosure materialPolycarbonate, stainless steel
WeatherproofingIP54
Hardware
NFC frequency13.56 MHz
NFC technologyISO/IEC 14443 Type A
MIFARE DESFire EV3 4K
UniFi Access Proprietary Security Protocol
Ambient operating temperature-10 to 45° C (14 to 113° F)
Ambient operating humidity10 to 90% noncondensing
CertificationCE